1260-Prime-LC-Separation-Science-header-banner.jpg

ABOUT

The Agilent 1260 Infinity II Prime LC is the most capable LC for everyday analyses. With high-performance instrumentation that provides a low delay volume, an extended pressure range of up to 800 bar, and superior quaternary mixing, the 1260 Infinity II Prime LC enables higher precision and accuracy in routine HPLC. Plus, it’s the ideal choice for LC/MS. What’s more, the 1260 Infinity II Prime LC includes automated solutions to simplify mobile phase blending and method transfer—delivering convenience that gives you an advantage in your daily work.

WinnerBadge_2018-png_smallThe Agilent 1260 Infinity II Prime LC is the winner of the SelectScience award for Best New Separations Product of 2017, as voted for by scientists across the globe.

WHITE PAPER
Improving Return on Investment in Liquid Chromatography with the InfinityLab LC Series

WhitePaperThumbThis White Paper illustrates how the new capabilities of the 1260 Infinity II Prime LC can provide up to 80,000 USD of incremental economic value per year compared to a conventional LC system. The economic value includes: reduced cost of operation, reduced downtime, more samples per day, and the utilization of one system for many methods. Use this White Paper as a resource for calculating the financial benefits of replacing your old instrumentation with a new 1260 Infinity II Prime LC.

Request White Paper >

VIDEO
Tired of Manually Mixing Mobile Phase?

If the answer is yes, take a look at the 'Blend Assist' function of the 1260 Infinity II Prime LC. With this you can reduce manual work during method development, and eliminate the waste and storage of premixed mobile phases. Watch the video to find out more...

BROCHURE
Achieve Convenience and Efficiency – Every Day in Every Way

BrochureThumbThe 1260 Infinity II Prime LC offers you latest instrumentation for highest performance. Its automation capabilities reduce the need for manual interaction. This brochure gives you a comprehensive overview of the system’s features, including:

  • Intelligent System Emulation Technology (ISET) for seamless method transfer from your older Agilent, Waters or Shimadzu instruments
  • BlendAssist software for automated mobile phase mixing
  • Agilent 1260 Infinity II Flexible Pump delivering a low delay volume, an extended pressure range of up to 800 bar, and superior quaternary mixing
  • Best compatibility with mass spectrometry, like Agilent’s remarkably small, but incredibly powerful Ultivo Triple Quadrupole LC/MS system

Read Brochure >

APPLICATION NOTES
Emulation of the Agilent 1200 Series LC for the Analysis of Antihistaminic Drugs

App4ThumbThis Application Note describes the separation of a mixture of five antihistaminic drugs. The drug mixture was analyzed first on an Agilent 1200 Series Quaternary LC. The analytical method was then transferred to a 1260 Infinity II Prime LC using Intelligent System Emulation Technology (ISET).

Request Application Note >


Emulation of a Waters Alliance LC for the Analysis of Metoclopramide and its Impurities

AppNote6_Thumb-1This Application Note shows the straightforward transfer of an analytical method from the Waters Alliance 2695 LC to a 1260 Infinity II Prime LC ISET.

Request Application Note >


Fast Optimization of Solvent Composition Using BlendAssist

App5ThumbThe Agilent 1260 Infinity II Flexible Pump with BlendAssist can be used to vary buffer or modifier concentration using ternary or quaternary gradients. This Technical Overview used BlendAssist for two different approaches.

Request Technical Overview >


The Agilent 1260 Infinity II Flexible Pump

App3ThumbThe precision of retention times of the 1260 Infinity II Flexible Pump was evaluated under demanding conditions and compared to the 1260 Infinity II Binary Pump. In addition, the composition accuracy, delay volume, and flow accuracy of both pumps were also evaluated by running step gradients.

Request Technical Overview >


Multiresidue Pesticides Analysis in Food Matrices

App1ThumbThis study demonstrates robust screening, and sensitive quantitation of 246 pesticide residues and their metabolites in complex food matrices using the Agilent Ultivo Triple Quadrupole LC/MS system.

Request Study >


Analysis of Mycotoxins in Food Matrices

App2ThumbThis study shows the accurate quantitation of 12 regulated mycotoxins in commonly regulated foods in using the Agilent Ultivo Triple Quadrupole LC/MS system.

 

Request Study >