Download your copies...



Agilent_pink_grapefruitReduced Carryover and Increased Reproducibility in the Analysis of Cold‑pressed Pink Grapefruit Essential Oil
The analysis of cold-pressed citrus essential oils, such as pink grapefruit, can be challenging due to the presence of higher molecular weight aromatic compounds, which can cause carryover or long run times. The Agilent J&W DB-HeavyWAX column, with a maximum operating temperature of 280 °C isothermal and 290 °C programmed, can operate at temperatures greater than traditional WAX-type columns. The increased temperature range allows faster and more reproducible analysis of compounds in cold-pressed pink grapefruit oil over extended periods of time. 

 


Agilent_endrin_and_DDTEndrin and DDT Stability Study for Drinking Water Methods with an Agilent 8890 GC/5977B GC/MSD Combined System
Endrin and 4,4'-DDT, organochlorine pesticides, can be used to determine flowpath inertness and cleanliness of a gas chromatography (GC) system. Active sites, matrix, or septum particles, and high temperatures, especially in the inlet, can cause the degradation of 4,4'-DDT to 4,4'-DDE and 4,4'-DDD. This application brief demonstrates that the Agilent 8890 GC can meet the instrumet performance check criteria established by US EPA Method 525.2 and Method 525.3 as well as other internal standards for drinking water quality.

 

 

Agilent_multiresidue_pesticide_analysisMultiresidue Pesticide Analysis in Food Matrices with an Ultra Inert Splitless Glass Frit Liner by GC/MS/MS
Pesticides in food matrices can be sensitive to inlet conditions, including the type of barrier in the liner, whether this is glass wool, dimples, or sintered frit. A multiresidue pesticide analysis method using gas chromatography/tandem quadrupole mass spectrometry (GC/MS/MS) was used to evaluate the efficacy of the Agilent Ultra Inert splitless sintered glass frit liner. 



 


Agilent_e-Cigarette_liquidAnalysis of E-Cigarette Liquid by 7890 GC and Intuvo 9000 Using an Agilent J&W DB-HeavyWAX GC Column
This application note demonstrates the use of the Agilent J&W
DB-HeavyWAX GC column for the analysis of e-cigarette liquid using an Agilent 7890 and Agilent Intuvo 9000 gas chromatograph. E-cigarette liquids can contain many fruit flavor compounds that require a higher final temperature or longer run time to elute off the column. The
DB-HeavyWAX has a maximum isothermal temperature of 280 °C and programmed temperature of 290 °C, with increased thermal stability, allowing for the efficient analysis of later eluting and higher boiling compounds.

 

Complete the form on the right to download your free copies of these application notes.