Applications eBook
Complete the form on the right to download your personal copy of the 'Food Testing & Environmental Analysis' eBook. This 43-page publication covers the applications detailed below.
Estimation of Ethylene Oxide and Ethylene Chlorohydrin in Sesame Seeds Using Agilent 8890 GC and 7000D Triple Quadrupole MS System
The method demonstrated in this work is useful for detecting ethylene chlorohydrin as a marker of fumigation of sesame seeds with ethylene oxide using the 8890 GC system coupled with the 7000D triple quadrupole mass spectrometer.
Low Calibration Limit Research for Multiresidue Pesticides in Milk Using the Agilent 8890/7010B and 7890B/7000C Triple Quadrupole GC/MS Systems
This application note describes two GC/MS/MS platforms that are both are applicable for pesticide analysis in milk and their corresponding linearity ranges, respectively.
Use of Salt to Increase Analyte Concentration in SPME Headspace Applications
This application demonstrates how the addition of salt to the sample matrix will often lower the partitioning coefficient (K) for some target analytes, thus increasing the concentration of analytes in the headspace.

Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME
This application note showcases a solid phase microextraction (SPME) gas chromatography/mass spectrometry (GC/MS) method to analyze the free-form volatile phenols associated with smoke impact.

Analysis of 1,4-dioxane in Water by Purge and Trap and Triple Quadrupole GC/MS
The method presented in this application note presents a sensitive, robust, and selective method to determine 1,4-dioxane in water using EPA 8260D purge and trap methodology.
Full Scan Quantitative Analysis of Semivolatile Organic Compounds
In this study, the Agilent 7000D triple quadrupole GC/MS system was used for the analysis of semivolatile organic compounds (SVOCs) in full scan data acquisition mode.
Plus also access these accompanying Application Compendiums ...
Advances in Food Testing & Environmental Analysis Application Compendium
This 65-page application compendium outlines a range of methods from food and beverage testing to dioxin and volatile organic compounds analysis.
Food & Environmental Application Compendium
This 8-page application compendium outlines applications that specifically use Agilent's 7250 GC/Q-TOF system, demonstrating its capability to manage a variety of food and environmental analyses. Whether used in complex metabolomics studies, pesticide screening in challenging matrices, or compound identification in herbal extracts, quadrupole time-of-flight GC/MS is shown to provide the ultimate in performance.
To view the Applications eBook and the Application Compendiums complete the form on the right.