---
title: Methods & Applications for Food Analysis
description: Applications and solutions for mycotoxin analysis, pesticide analysis, glyphosphate detection in bottled drinking water and edible oil determination.
---

[Chromatography Forum](http://www.chromforum.org/)

[Analytical Training Solutions](https://www.analytical-training-solutions.com)

[日本語](https://www.sepscience.com/japan)

[![Separation Science](https://learning.sepscience.com/hubfs/Sepscience_Dec2016/images/-resized-strch-SepSci_WebHeader_v3.png)](https://www.sepscience.com/)

[Chromatography Forum](http://www.chromforum.org/)

[Analytical Training Solutions](https://www.analytical-training-solutions.com)

[日本語](https://blog.sepscience.com/japan)

[Sign Up for Newsletter](https://www.sepscience.com/subscribe/)

![Restek_Header_Food_Analysis_1139x190_New](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Header_Food_Analysis_1139x190_New.png?width=1139&height=190&name=Restek_Header_Food_Analysis_1139x190_New.png)

Separation Science, in collaboration with Restek, offers its latest 'Food Analysis' eBook featuring new applications and methods to help you achieve faster analysis times and increase sample throughput. Applications, articles and solutions are provided for the analysis of furan and alkylfurans, mycotoxin analysis, pesticide analysis, glyphosphate detection in bottled drinking water and edible oil determination. 

### Applications eBook

Complete the form on the right to download your personal copy of the new 'Food Analysis' eBook. This 77-page publication covers the applications detailed below.

![Food_App1_New](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Food_App1_New.png?width=90&height=113&name=Food_App1_New.png)Analysis of Furan and Alkylfurans in Food Commodities by SPME Arrow GC-MS  
In this study, SPME Arrow sample preparation was tested for the analysis of furan and alkylfurans in baby formula and coffee samples. Optimized conditions were established for GC-MS analysis using a PAL CTC autosampler and an Rxi-624Sil MS column. Results demonstrated the method may be suitable for diverse sample types containing both high and low concentrations of furan and alkylfurans.

![Restek_Food_App2_New](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App2_New.png?width=90&height=113&name=Restek_Food_App2_New.png)Comprehensive Mycotoxin Analysis: Simultaneous Determination of *Alternaria* Toxins, Ergot Alkaloid Epimers, and Other Major Mycotoxins in Various Food Matrices by LC-MS/MS  
In this study, a simplified sample preparation procedure and a reliable LC-MS/MS analytical method were developed for the simultaneous analysis of 37 regulated and emerging mycotoxins, including five *Alternaria* toxins, six major ergot alkaloids and their corresponding epimers, and priority mycotoxins from other classes.

![Restek_Food_App3_New](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App3_New.png?width=90&height=113&name=Restek_Food_App3_New.png)Analysis of Ergot Alkaloid Mycotoxins in Blended Flour by LC-MS/MS Under Acidic Conditions  
This application uses a Raptor Biphenyl column and acidic conditions to allow concurrent analysis of ergot alkaloids with other mycotoxins of interest. Suitability of this method for multiresidue mycotoxin testing provides food safety labs with a more efficient workflow and the time-saving benefit of combined analysis.

![Restek_Food_App4_New](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App4_New.png?width=90&height=113&name=Restek_Food_App4_New.png)Multi-Mycotoxin Method for *Alternaria* Toxins, Ergot Alkaloid Epimers, and Other Major Mycotoxins in Food  
Here, we show the simultaneous analysis of *Alternaria* toxins, ergot alkaloid epimers, and other major mycotoxins using a simple sample preparation procedure and a Raptor Biphenyl column run under acidic conditions. Under these column- and MS-friendly conditions, accurate quantitative results were obtained in a fast, 11-minute total cycle time run.

![Restek_Food_App1](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App1.png?width=90&name=Restek_Food_App1.png)Avoid Mycotoxin Quantitation Errors When Using Stable Isotope Dilution Assay (SIDA)  
This application note shows how there are significant benefits to using the stable isotope dilution assay (SIDA) calibration approach for mycotoxin analyses — the biggest being able to use a single calibration curve for multiple matrix types.

![Restek_Food_App2](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App2.png?width=90&name=Restek_Food_App2.png)Speed Up Multiresidue Pesticides Analysis in Food with Low-Pressure GC-MS  
Multiresidue pesticides analysis is a cornerstone of food safety testing, and labs are generally under pressure to manage both a high volume of samples and rapid turnaround time requirements. This application note demonstrates the speed gains of LPGC-MS pesticides analysis as an effective way to increase sample throughput in busy food labs needing faster methods.

![Restek_Food_App3](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App3.png?width=90&name=Restek_Food_App3.png)Simple Large Volume Injection Method for Trace-Level Glyphosate in Bottled Drinking Water  
In the method for glyphosate in water shown here, an anion-exchange mechanism in the column provides enough retention under the initial mobile phase conditions to allow large volumes (500 μL) of bottled water to be injected, which is a very simple way to improve low-level sensitivity.

 

![Restek_Food_App4](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App4.png?width=90&name=Restek_Food_App4.png)

Analysis of Pesticides in Oranges: Exploring QuEChERS for Peel, Pulp, and Whole Fruit  
This article discusses the analysis of pesticides in oranges using QuEChERS and looks at the effect of extracting whole fruit versus separate peel and pulp samples.

 

![Restek_Food_App5](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/eBook_Food_Analysis/Restek_Food_App5.png?width=90&name=Restek_Food_App5.png)

Robust GC Analysis of Glycerides in Edible Oils  
The method described shows how labs performing GC analysis of glycerides in edible oils will benefit from the reproducible retention times, longer column lifetimes, and consistent performance of low-bleed Rxi-65TG columns.

 

 

To view the eBook complete the form on the right.

If you have a colleague that may be interested in the subject of this eBook, please forward them the link below.

[![Forward to a colleague >](https://no-cache.hubspot.com/cta/default/2322077/23caada3-dc80-4dd2-b231-58e58ab30f5a.png)](https://cta-redirect.hubspot.com/cta/redirect/2322077/23caada3-dc80-4dd2-b231-58e58ab30f5a)

**Sponsor:**

![restek](https://learning.sepscience.com/hs-fs/hubfs/Companies/Restek/restek.png?width=200&name=restek.png)

 

### Download the new eBook...

Registrants for this eBook are covered by the Eclipse Business Media [Privacy Policy](http://www.sepscience.com/privacy-policy).

Eclipse Business Media Ltd, Regd in England, No. 06513189, Woodview, Bull Lane Industrial Estate, Sudbury, CO10 0FD, United Kingdom, T +44 (0)161 818 7434, [info@sepscience.com](mailto:info@sepscience.com)

 

Eclipse Business Media Ltd needs the contact information you provide to us to contact you about our products and services. You may unsubscribe from these communications at any time. For information on how to unsubscribe, as well as our privacy practices and commitment to protecting your privacy, check out our [Privacy Policy](https://www.sepscience.com/privacy-policy/) or contact [privacy@labxmediagroup.com](mailto:privacy@labxmediagroup.com) 

Copyright © 2025. All rights reserved

[Contact Us](https://www.sepscience.com/contact-us/)  
[Advertise with Us](https://www.sepscience.com/advertise-with-us/)